Spotter struck in face by winch cable

What happened?

A winch truck was being unloaded from a float trailer in preparation for a rig move. The winch was centrally located behind the cabin of the truck and the winch line was extended and secured to a main bed roll pin by a lift sling. During the unloading, the winch power take-off (PTO) switch (which drives the winch) engaged the winch, tightening the winch line, which bent the pin and released the line under tension. The released line whipped around, glancing a spotter in the face who was standing beside the winch truck. No significant injury occurred to the spotter.

How did it happen?

A mechanical failure of an interlock/inversion valve which did not disengage correctly, allowing the winch to operate while the truck was in gear.

Key Issues

  • The winch truck driver had placed the truck into low range, which should have ensured the winch could not operate while the truck was in gear.
  • The driver had also set the PTO switch to a disengaged position, which should have stopped the winch from operating.
  • A mechanical inspection revealed that the aforementioned controls had failed due to a mechanical failure of an interlock/inversion valve which did not disengage correctly allowing the winch to operate while the truck was in gear, unbeknownst to the driver.
  • There had been no set preventative maintenance on the failed interlock valve.
  • SPO's were found to have been followed.

Recommendations

Operators should consider the merits of

  • Reviewing their risks and controls for winch trucks which have similar winch systems.
  • Classifying the interlock valve as a consumable and set a preventative maintenance schedule (ie replace every 6 months).
  • Implementing a rope/sling register and winch register per rig management system.

Authorised by William Date -

Contact: Paul Bergin, Manager Investigations , +61 7 3199 8027

Issued by Queensland Department of Natural Resources, Mines and Energy