Workplace exposure limits | Resources Safety & Health Queensland Skip to content

Workplace exposure limits

New Safe Work Australia Workplace Exposure Limits (WELs) take effect on 1 December 2026, but there is no change to the statutory exposure limits that apply to Queensland resources industries where exposure limits are directly addressed by specific resources safety and health legislation administered by RSHQ.

Where there are limits prescribed by resources safety and health legislation, recognised standards and guidance notes these will continue to apply. For example, for mining and quarrying operations the Workplace exposure standards for airborne contaminants (WES) published by SWA will continue to apply where applicable under the resources safety and health legislation, rather than the WELs.

Where no limit is prescribed, there is other guidance, such as the WELs, which can be used as guidance for risk management in specific industry settings for exposure levels. Further guidance details will be available on the RSHQ website shortly. For coal mines access this link for a table listing prescribed legislative and guidance values.

RSHQ will continue to monitor scientific, technical and regulatory developments and any future changes to legislation, recognised standards or guidance notes would be subject to consultation with stakeholders.

WELs and transitional arrangements for workplaces regulated by Workplace Health and Safety Queensland (WHSQ) are available from the WHSQ website.

Workplace exposure limits for Queensland Coal Operations

How to read this table

The Coal Mining Safety and Health Regulation 2017 contains specified exposure limits that must be complied with by coal operations as referred to below. Where there is no prescribed specific exposure limit in the legislation, there is still an obligation on operators to manage risk and to ensure that risk is at an acceptable level, namely that the level of risk is within acceptable limits and as low as reasonably achievable. Guidance on exposure limits such as in the WES or WELs should be used to consider what an acceptable limit is when there are no prescribed limits for that contaminant in the coal mining safety and health legislation.

CONTAMINANTEXPOSURE LIMITS
SURFACE COAL MINES
(AND SURFACE AREAS OF OPERATING UNDERGROUND MINES)
UNDERGROUND COAL MINES
Aluminium (welding fumes) 1 mg/m3 (TWA)
SWA Workplace exposure limit
1 mg/m3 (TWA)
SWA Workplace exposure limit
Arsenic and soluble compounds 0.01 mg/m3 (TWA)
SWA Workplace exposure limit
0.01 mg/m3 (TWA)
SWA Workplace exposure limit
Benzene 0.2 ppm (TWA)
SWA Workplace exposure limit (from 1/6/2027)
0.2 ppm (TWA)
SWA Workplace exposure limit (from 1/6/2027)
Cadmium and compounds (as Cd) 0.001 mg/m3 (TWA)
SWA Workplace exposure limit
0.001 mg/m3 (TWA)
SWA Workplace exposure limit
Carbon dioxide in coal mines 5,000 ppm (TWA)
30,000 ppm (TWA)
SWA Workplace exposure limit
12,500 ppm (TWA)
30,000 ppm (Max)
CMSHR s 360
Carbon monoxide 20 ppm (TWA)
SWA Workplace exposure limit
30 ppm
CMSHR Schedule 6
Chromium (metal), (II, III) 0.5 mg/m3 (TWA)
SWA Workplace exposure limit
0.5 mg/m3 (TWA)
SWA Workplace exposure limit
Chromium VI* 0.05 mg/m3 (TWA)
SWA Workplace exposure standard (WES)
0.05 mg/m3 (TWA)
SWA Workplace exposure standard (WES)
Coal dust containing < 5% quartz (respirable dust) 1.5 mg/m3 (TWA)
CMSHR s 89
1.5 mg/m3 (TWA)
CMSHR s 89
Cobalt (metal and inorganic compounds) 0.02 mg/m3 (TWA)
SWA Workplace exposure limit
0.02 mg/m3 (TWA)
SWA Workplace exposure limit
Copper fume 0.2 mg/m3 (TWA)
SWA Workplace exposure limit
0.2 mg/m3 (TWA)
SWA Workplace exposure limit
Diesel particulate matter^ 0.01 mg/m3 (TWA)
Sub-micron fraction
0.05 mg/m3 (TWA)
Sub-micron fraction
Industry-agreed limit
Formaldehyde 1 ppm (TWA)
2 ppm (STEL)
SWA Workplace exposure limit
1 ppm (TWA)
2 ppm (STEL)
CMSHR Schedule 6
Hydrogen sulphide 10 ppm (TWA)
15 ppm (STEL)
SWA Workplace exposure limit
10 ppm (TWA)
15 ppm (STEL)
CMSHR Schedule 6
Inhalable dust (PNOC) 10 mg/m3 (TWA)
SWA Workplace exposure limit
10 mg/m3 (TWA)
SWA Workplace exposure limit
Iron oxide fume 5 mg/m3 (TWA)
SWA Workplace exposure limit
5 mg/m3 (TWA)
SWA Workplace exposure limit
Isocyanates (as NCO) 0.02 mg/m3 (TWA)
0.07 mg/m3 (STEL)
SWA Workplace exposure limit
0.02 mg/m3 (TWA)
0.07 mg/m3 (STEL)
SWA Workplace exposure limit
Lead, inorganic dusts and fumes (as Pb) 0.05 mg/m3 (TWA)
SWA Workplace exposure limit
0.05 mg/m3 (TWA)
SWA Workplace exposure limit
Manganese fume, dust and compounds (as Mn) 0.1 mg/m3 (inhalable) (TWA)
0.02 mg/m3 (respirable) (TWA)
SWA Workplace exposure limit
0.1 mg/m3 (inhalable) (TWA)
0.02 mg/m3 (respirable) (TWA)
SWA Workplace exposure limit
Methyl isocyanate 0.047 mg/m3 (TWA)
SWA Workplace exposure limit
0.047 mg/m3 (TWA)
SWA Workplace exposure limit
Nickel metal fume and insoluble compounds 0.1 mg/m3 (TWA)
SWA Workplace exposure limit
0.1 mg/m3 (TWA)
SWA Workplace exposure limit
Nitric oxide 2 ppm (TWA)
SWA Workplace exposure limit
25 ppm (TWA)
CMSHR Schedule 6
Nitrogen dioxide 3 ppm (TWA)
5 ppm (STEL)
SWA Workplace exposure limit
3 ppm (TWA)
5 ppm (STEL)
CMSHR Schedule 6
Nitrous oxide 25 ppm (TWA)
SWA Workplace exposure limit
25 ppm (TWA)
CMSHR Schedule 6
Ozone 0.1 ppm (Peak limitation)
SWA Workplace exposure limit
0.1 ppm (Peak limitation)
SWA Workplace exposure limit
Phenol 1 ppm (TWA)
SWA Workplace exposure limit
1 ppm (TWA)
Recognised Standard 16
Phenyl isocyanate 0.024 mg/m3 (TWA)
SWA Workplace exposure limit
0.024 mg/m3 (TWA)
SWA Workplace exposure limit
Silica - crystalline (respirable) 0.05 mg/m3 (TWA)
CMSHR s 89
0.05 mg/m3 (TWA)
CMSHR s 89
Sulphur dioxide 2 ppm (TWA)##
5 ppm (STEL)
SWA Workplace exposure limit
2 ppm (TWA)##”. 2 ppm (TWA)
5 ppm (STEL)
CMSHR Schedule 6
Welding fume 1 mg/m3 (TWA)
SWA Workplace exposure limit
5 mg/m3 (TWA)
CMSHR Schedule 6
Zinc oxide dust and fume 2 mg/m3 (TWA)
10 mg/m3 (STEL)
SWA Workplace exposure limit
2 mg/m3 (TWA)
10 mg/m3 (STEL)
SWA Workplace exposure limit

NOTES

* An action limit of 0.025mg/m3 (TWA- shift adjusted) will prompt review of controls and an exceedance of 0.05mg/m3 (TWA - shift adjusted) would require a comprehensive investigation to the standard that is set out in Recognised Standard 14.

^ The guideline limit value for diesel particulate matter (DPM) specified for Queensland coal mines applies to underground coal mines only.

## An action limit of 1ppm (TWA-shift adjusted) will prompt review of exposure monitoring data and controls. Further to this, sites will be encouraged to apply TARPs with triggers linked to personal gas detector (PGD) measurements above 0.25ppm (SWA STEL).

Abbreviations: TWA = time-weighted average; STEL = short-term exposure limit; Max = maximum limit; PNOC = particles not otherwise classified.

Last updated: 24 Nov 2026