| Petroleum and gas safety alert | No.43 V 1 | 21 September 2009
Broken leg from coal seam gas sampling incident involving high pressure
What happened?
A gas sampling contractor was struck by a flying fragment from an exploded gas filter. The filter had been exposed to a pressure that exceeded its design specifications (1,600kPa). The filter was being used as part of a gas sampling kit on the high pressure (9,000kPa) product end of a coal seam gas processing plant. One of the contractor technicians undertaking the work sustained a broken leg and related soft tissue damage.
While the exact causes of the incident are still to be determined, this safety alert is a reminder to all operators, staff, their employees and contractors to take particular care when selecting components to be used on high pressure gas systems.
Safety issues identified
- Incorrect selection of filter type for the application.
- Contractors had no formal training in high pressure sampling and had not directly undertaken work before.
- Lack of risk assessment, identification of hazards and use of standard operating procedures when taking gas samples.
- Poor implementation and adherence to existing:
- company policies and procedures
- contractor supervision.
Recommendations
- Gas sampling connection and disconnection procedures to include requirements for correct sequence of events and specify the type and rating of components that form the sampling kit.
- Dedicated sampling point to be provided if regular sampling is a standard requirement at the facility.
- Organizations to immediately review their:
- hazard registers
- risk assessments
- standard operating procedures (SOP)
- job safety analyses (JSA)
- contractor training and supervision requirements.
Attention: All workers and companies involved in the oil and gas industry.
Contact: Chief Inspector, Petroleum and Gas gassafe@dnrm.qld.gov.au
Issued by Queensland Department of Employment, Economic Development and Innovation
Find more Safety and Health Alerts
Search the hazards database