Mineral Mines & Quarries Inspectorate | Alert | No.475 V 1 | 08 June 2026
Ineffective isolation of generating and mobile plant
Summary
- Recent inspections by RSHQ continue to identify issues with generating and mobile plant.
- Issues include the absence of isolation facilities, isolation points that cannot be locked, and isolation systems that are incompatible and therefore ineffective.
- This alert includes learnings for site senior executives (SSEs).
Issue Explained
- Ineffective isolation of generating and mobile plant creates significant risk. This is because inadvertent energisation during maintenance can expose workers to crush, shear, entanglement, injection and electric shock hazards.
- Inspections undertaken by RSHQ continue to identify generating and mobile plant without isolation facilities or isolation facilities that are not capable of being locked in the off position.
- Recent inspections have also identified isolation facilities on mobile plant, and personal isolation locks in use, that are incompatible and do not enable effective isolation.
Learnings
- SSEs should audit all generating and mobile plant in operation at their mines to ensure each item is fitted with an appropriate energy isolation facility.
- SSEs should also ensure the isolation facility:
- is clearly marked or labelled as the isolator for the plant
- is capable of being locked out and tagged (Figure 1, from a recent inspection at a surface mine, depicts a diesel electric generator’s battery isolator that is not capable of being locked in the off position)
- cannot be operated or actuated when an isolation lock has been applied (Figure 2, from a recent inspection at a surface mine, depicts a piece of heavy mobile plant’s battery isolator with a personal isolation lock and tag applied that has been actuated from the intended off position).
- SSEs should review their safety and health management system to ensure that appropriate processes are incorporated to:
- prevent generating and mobile plant being introduced into service on the mine without isolation facilities that are compatible with the mine’s isolation and lock-out procedures
- prevent the use of personal or group isolation locks that are not compatible with generating and mobile plant isolation facilities in service on the mine.

Figure 1 - Non lockable isolation facility
Figure 2 - Actuated isolation facility fitted with isolation lock
RSHQ issues Safety and Health Alerts to highlight serious incidents, raise awareness of risks and prompt assessment of existing controls.
Investigations are ongoing. Information within this Safety and Health Alert is accurate at the time of publishing and further detail may be released as investigations progress.
References and further information
- Guidance Note QGN02 Isolation of Plant accessible here: Recognised standards, guidelines and guidance notes
- Mining and Quarrying Safety and Health Regulation 2017 (Qld)
Contact: QldMinesInspectorate@rshq.qld.gov.au
Issued by Resources Safety & Health Queensland
Placement: Place this announcement on noticeboards and ensure all relevant people in your organisation receive a copy.
Find more Safety and Health Alerts