| Mines safety bulletin | No.120 V 1 | 20 September 2012
Exposure to toxic gases associated with spontaneous combustion at surface coal mines
What happened?
Surface coal mine workers were exposed to toxic gases, associated with spontaneous combustion, including carbon monoxide and sulphur dioxide. The health of some of these workers was affected and most were taken to hospital for observation.
How did it happen?
Spontaneous combustion in coal mines is generally caused by the oxidation of coal and other carbonaceous materials. Toxic gases may be released during this process.
Where is the risk?
In 2012, several surface coal mines experienced the release of toxic gases associated with spontaneous combustion. These releases exposed some mine workers to harmful levels of gases, including carbon monoxide (CO) and sulphur dioxide (SO2) which are the main gases associated with spontaneous combustion in Queensland surface coal mines.
These gases affect the body in different ways. CO restricts the body's ability to absorb oxygen and SO2 irritates the eyes and respiratory system. Individual tolerances to either of these gases vary, e.g. asthmatics might be highly sensitive to levels of SO2 that do not affect the majority of coal mine workers. On the other hand, smokers often have a greater tolerance to carbon monoxide exposure.
For more comprehensive information on the health effects of these and other gases found on surface coal mines, see Mines safety bulletin 61 Flammable and toxic gases in open cut coal mines.
Recommendations
Controlling exposures
- Controlling toxic gases, like any hazard, should be in accordance with the hierarchy of control. An effective spontaneous combustion management program should consider controls for preventing or minimising spontaneous combustion.
- Lower level administrative controls and the use of PPE and monitors, may be important in the overall control strategy but should not be the primary control.
- The focus should be on prevention. All controls should be detailed in a Hazard Management Plan.
- Spontaneous combustion can be controlled by removing either the fuel, heat or oxygen
- Most practical control and prevention strategies focus on removing oxygen, usually by interrupting the oxygen pathway to the fuel (coal or carbonaceous material). Applying covering layers of inert material such as clays, which can retain residual moisture, reduces the rate at which oxygen can penetrate the spoil pile.
Hazard management plan
The recommendations below refer to the hazard management plan.
- Focus on preventing spontaneous combustion through mine design and mining methods.
- Introduce capability for early detection and prediction of spontaneous combustion using techniques such as thermal imagery, geological mapping and core sampling. This information can be used to plan mining methods, etc before encountering the 'reactive ground'.
- Detail inspection regimes for identifying spontaneous combustion events.
- Detail processes for treating and managing spontaneous combustion once it's identified. Consider environmental factors such as prevailing winds and position of personnel and equipment in relation to the direction of drift of spontaneous combustion products.
- Mark all identified spontaneous combustion areas as hazardous areas on a mine plan. The status of each identified area should be continuously monitored and updated.
- Consider delineating spontaneous combustion areas by trenching filled with water, mud, grout or other non-combustible material to prevent the spread of fire or heatings.
- Detail a personal and area monitoring program that references trigger action response plans, (TARPs), for each toxic gas and corresponding actions when certain gas levels are triggered. Develop these levels in consultation with technical experts. Monitoring will also enable mines to decide on the effectiveness of controls and extent of exposure.
- Allocate responsibilities and accountabilities for anyone assigned a task or required to implement a task under this plan.
- Reference all relevant safe operating procedures (SOPs) for all tasks required under this plan (eg. monitoring of toxic gases, mining in heatings, establishing emergency procedures for toxic gas in the work environment, stockpile management). Develop these SOPs in accordance with section 10 of the Coal Mining Safety and Health Regulation 2001.
Section 142 of the Coal Mining Safety and Health Regulation 2001, requires a mine's safety and health management system to provide for protecting persons from risks associated with exposure to flammable or toxic gas. This includes gas due to spontaneous combustion.
In addition it is necessary to:
- Provide training to coal mine workers required to work under the relevant SOPs. This may include the use of portable gas monitors and the correct fitting and maintenance of respiratory protection.
- Conduct emergency response exercises that consider toxic gas exposure and the recovery/treatment of affected coal mine workers.
- Educate the workforce on toxic gases, their health effects and the relevant exposure standards.
- Communicate gas monitoring results, location of spontaneous combustion events and actions taken to control them with the workforce.
- Provide adequate resources such as portable and fixed monitoring equipment.
Contact: minesafetyandhealth@dnrm.qld.gov.au
Issued by Queensland Department of Natural Resources and Mines
Find more Safety and Health Alerts