Dead-man control defeated on QDS bolter | Resources Safety & Health Queensland Skip to content
Print notice
Alert Banner

Coal Inspectorate | Alert | No.481 V 1 | 13 July 2026

Dead-man control defeated on QDS bolter

Summary

  • During a pre-start inspection of a QDS bolter, an operator identified a plastic zip-tie restraining a dead-man lever in the 'on' position.
  • Safety critical hold-to-run controls must not be restrained, bypassed or defeated, and their correct operation must be verified before the plant is used.
  • The machine was stood down and moved to a safe location for investigation. The investigation is ongoing.

Issue explained

During a pre-start inspection at an underground coal mine, an operator identified a plastic zip-tie restraining the dead-man lever of a QDS bolter in the 'on' position.

The zip-tie bypassed the intended two-handed operating safety measure and could allow hydraulic functions without continuous engagement of the dead-man control. This risks accidental activation and could expose people near the machine to crush, entanglement and struck-by hazards, with the potential for serious injury or death.

The machine was immediately stood down, the district ERZ controller was notified, and the bolter was moved to a safe location for further examination. No injury was reported. The event was notified to RSHQ as a high potential incident.

The investigation is ongoing and, at the time of publication, has not established who installed the zip-tie or when it was installed.

QDS bolter control station showing the zip-tie restraining the dead-man lever

Figure 1 - QDS bolter control station showing the zip-tie restraining the dead-man lever.

QDS bolter involved in the incident

Figure 2 - QDS bolter involved in the incident.

Learnings

  • Machinery should only be operated as intended and in line with established site procedures.
  • Do not alter a safety-critical control, except through the mine’s formal plant-modification and change-management process. This should include risk assessment, competent engineering or designer input, authorisation, documentation and functional testing before the plant is returned to service.
  • Site senior executives (SSEs) should ensure QDS bolters and similar hydraulically operated plant are inspected for any device or arrangement that restrains, bypasses or defeats a dead-man, hold-to-run, or other control.
  • Ensure pre-start inspections include a functional test that checks if safety-critical controls are working and respond as expected, including stopping or preventing further actuation of the relevant hazardous function.
  • A visual inspection alone may not identify a defeated or ineffective controls.
  • Confirm that releasing the dead-man or hold-to-run control causes the machine to respond as designed, including stopping or preventing further actuation of the relevant hazardous function.
  • Restrained, bypassed, damaged or non-functioning safety-critical controls should be treated as serious defects. Stand the plant down and apply the mine’s defect-management, isolation and tagging procedures. Preserve the condition of the plant and notify the relevant supervisor or ERZ controller so the circumstances can be investigated.
  • Supervisors should periodically verify the quality of pre-start inspections and reinforce that safety controls must not be defeated for operational convenience.
  • Inspect similar plant and review recent pre-start, defect and maintenance records for evidence of repeated defects, unauthorised alterations or ineffective functional checks.

RSHQ issues Safety and Health Alerts to highlight serious incidents, raise awareness of risks and prompt assessment of existing controls.

Investigations are ongoing. Information within this Safety and Health Alert is accurate at the time of publishing and further detail may be released as investigations progress.

References and further information

Authorised by Jacques Le Roux - Chief Inspector – Coal

Contact:

Issued by Resources Safety & Health Queensland

Safety: This information is a guide only and is issued to promote safety through experience. It is not to be taken as a statement of law and must not be construed to waive or modify any legal obligation.
Placement: Place this announcement on noticeboards and ensure all relevant people in your organisation receive a copy.