Stored energy while manual handling | Resources Safety & Health Queensland Skip to content
Print notice

| Mines safety alert | No.165 V 1 | 31 July 2007

Stored energy while manual handling

Mine Type

All coal mines

Incident

A coal mine worker was injured while conducting a manual handling task on a wire towing sling.

A wire towing sling was towed into position by a light vehicle to recover bogged equipment. The wire towing sling was then manually handled into position to attach to the bogged equipment. The wire towing sling moved unexpectedly, causing injury to the coal mine worker.

Equipment

Wire towing sling.

Hazard

Stored energy in the wire towing sling was not identified in the manual handling SOP, training, or by the coal mine worker.

Cause

The wire towing sling was towed into a semi circle by a light vehicle. This compressed the wire towing sling into a smaller semi circle than it would normally lay. When the sling was manually handled by the coal mine worker, the stored energy in the wire towing sling caused it to straighten unexpectedly, injuring the coal mine worker.

Comments and recommendations

  • All coal mines need to ensure that manual handling procedures and training includes identification of stored energy.
  • All coal mines review manual handling procedures and risk assessments to include the hazard of stored energy while manually handling items such as slings.

Authorised by Michael Downs -

Contact:

Issued by Queensland Department of Mines and Energy