Slurry pump explosion
What happened?
A 10/8 slurry pump exploded after becoming deadheaded during operation. The explosion propelled the associated suction pipe work several metres together with the cover plate causing significant damage to surrounding structures. There was no worker in the vicinity at the time.
How did it happen?
Recommendations
- Change management processes should occur whenever a proposed modification to a process may have an impact on the safety and health of workers. The modification should be authorised at an appropriate level of authority, and be documented and understood by operators.
- Where critical controls are in place to prevent catastrophic events, a regular check should be carried out to verify that the control is effective.
- Operators should have a basic understanding of the process and of the safety critical controls that are in place.
Contact: Richard Horsburgh, Authorised Officer , +61 7 4028 5623 Richard.Horsburgh@dnrm.qld.gov.au
Issued by Queensland Department of Natural Resources and Mines
Find more Safety and Health Alerts